DocumentCode
305113
Title
AC dissipation current waveform and space charge formation of water-tree-degraded polyethylene film
Author
Nagao, M. ; Akama, W. ; Yamamoto, T. ; Kosaki, M.
Author_Institution
Toyohashi Univ. of Technol., Japan
Volume
1
fYear
1996
fDate
20-23 Oct 1996
Firstpage
153
Abstract
The possibility of the new diagnostic method of water tree degradation is examined by observing the high field AC dissipation current waveforms and the space charge formation in water-tree-degraded low-density polyethylene (LDPE) films. The AC dissipation current waveforms of water-tree-degraded LDPE film contains more higher harmonic components than those of undegraded films. Furthermore, the differences between undegraded and water-tree-degraded films were observed in their space charge distribution. It can be speculated that the space charge was formed by the carrier injection from the water-tree-degraded region rather than the effect of the impurity ions in the bulk of the materials. The distortion of the high field AC dissipation current waveforms in water-tree-degraded LDPE films is considered to have some correlation to the space charge formation
Keywords
polyethylene insulation; power cable insulation; space charge; trees (electrical); AC dissipation current waveform; LDPE; carrier injection; higher harmonic components; power cable insulation; space charge formation; water-tree-degraded polyethylene film; Bridge circuits; Cables; Degradation; Dielectrics and electrical insulation; Frequency; Plastic films; Polyethylene; Space charge; Space technology; Trees - insulation;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Insulation and Dielectric Phenomena, 1996., IEEE 1996 Annual Report of the Conference on
Conference_Location
Millbrae, CA
Print_ISBN
0-7803-3580-5
Type
conf
DOI
10.1109/CEIDP.1996.564647
Filename
564647
Link To Document