DocumentCode
3060159
Title
A microwave multisine with known phase for the calibration of narrowbanded nonlinear vectorial network analyzer measurements
Author
Barel, A. ; Rolain, Y.
Author_Institution
Dept. Electr., VUB, Brussels, Belgium
Volume
3
fYear
1998
fDate
7-12 June 1998
Firstpage
1499
Abstract
A method is proposed to generate an RF multi-tone (up to 10 GHz) calibration signal with a very narrow harmonic spacing (down to 100 KHz) and a known phase relation between tones. This signal is requested for the phase calibration of a nonlinear vectorial network analyzer on a dense grid, as occurs when modulated signals are measured. The phase relation is traceable to a nose-to-nose calibrated microwave sampling oscilloscope.
Keywords
calibration; harmonics; microwave measurement; network analysers; 100 kHz to 10 GHz; RF multi-tone calibration signal; calibration; dense grid; microwave multisine; modulated signals; narrow harmonic spacing; narrowbanded nonlinear vectorial network analyzer; nose-to-nose calibrated microwave sampling oscilloscope; phase relation; Amplitude modulation; Calibration; Frequency measurement; Phase measurement; Phase modulation; Power harmonic filters; Sampling methods; Senior members; Signal analysis; Signal generators;
fLanguage
English
Publisher
ieee
Conference_Titel
Microwave Symposium Digest, 1998 IEEE MTT-S International
Conference_Location
Baltimore, MD, USA
ISSN
0149-645X
Print_ISBN
0-7803-4471-5
Type
conf
DOI
10.1109/MWSYM.1998.700659
Filename
700659