  • Abstract
    Active control is one way to cope with surge in compression systems. For this, a suitable combination of actuators and sensors must be selected. In this paper, the goal is to find a combination fulfilling the condition that a controller exists, which stabilizes the nominal model in the face of disturbances and actuator limitations. For a collection of linearizations of the nonlinear system, this condition is quantified as an ℋ norm bound on the closed-loops. Among the proposed actuators and sensors, the close-coupled valve and mass flow sensor are the most promising for the considered system, but a movable wall should be added to meet the specifications
  • Keywords
    H control; H optimisation; actuators; closed loop systems; compressors; nonlinear control systems; pressure sensors; valves; ℋ norm bound; active surge control; actuator limitations; close-coupled valve; closed-loops; compression systems; disturbances; linearizations; mass flow sensor; movable wall; nonlinear system; sensors; Actuators; Control systems; Costs; Mechanical engineering; Mechanical sensors; Nonlinear control systems; Nonlinear systems; Output feedback; Sensor systems; Surges;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Control Applications, 1997., Proceedings of the 1997 IEEE International Conference on
  • Conference_Location
    Hartford, CT
  • Print_ISBN
    0-7803-3876-6
  • Type

    conf

  • DOI
    10.1109/CCA.1997.627493
  • Filename
    627493