DocumentCode
3078486
Title
Human dermis ultrasound characterization: backscattering parameters between 22-45 MHz
Author
Lebertre, M. ; Ossant, F. ; Vaillant, L. ; Diridollou, S. ; Patat, F.
Author_Institution
Fac. de Med., LUSSI/GIP Ultrasons, Tours, France
Volume
2
fYear
2000
fDate
36800
Firstpage
1371
Abstract
The aim of this work was to determine the intra- and inter-individual variations of several acoustical parameters such as attenuation coefficient slope, backscatter coefficient and effective density of scatterers. These parameters and their trend versus depth were estimated in vitro, with a 35 MHz focused transducer, on fresh abdominal human dermis. The influence of the epidermis on the dermis backscatter coefficient was also investigated and discussed
Keywords
backscatter; bioacoustics; biomedical ultrasonics; skin; ultrasonic scattering; 22 to 45 MHz; ROI size; Rayleigh distribution; abdominal human dermis; attenuation coefficient slope; backscatter coefficient; backscattering parameters; depth dependence; echo envelope; effective density of scatterers; focused transducer; human dermis ultrasound characterization; interindividual variations; intraindividual variations; skin inhomogeneity; Acoustic scattering; Acoustic transducers; Attenuation; Backscatter; Dermis; Humans; In vitro; Scattering parameters; Ultrasonic imaging; Ultrasonic transducers;