• DocumentCode
    3078656
  • Title

    LV wall motion: from quantitative analysis to knowledge-based understanding

  • Author

    Baroni, M. ; Barletta, G. ; Fantini, F.

  • Author_Institution
    Florence Univ., Italy
  • fYear
    1989
  • fDate
    19-22 Sep 1989
  • Firstpage
    483
  • Lastpage
    486
  • Abstract
    An expert system for computer evaluation of cardiac function from left ventricle (LV) contours is under development. A description of normal and pathological ventricles has been assessed by statistical analysis and fuzzy logic. For this purpose LV contours of 16 normal subjects and 67 patients were manually digitized from RAO cineangiograms on a frame-by-frame or two-frame basis. Wall motion was analyzed with eight known quantitative methods. Regional shape and its dynamic changes were quantified by curvature and Fourier analysis. A rule-based scheme combining partial evidence in order to test clinical hypotheses is proposed
  • Keywords
    biomechanics; cardiology; expert systems; medical diagnostic computing; Fourier analysis; cineangiograms; clinical hypotheses; computer evaluation; curvature; fuzzy logic; knowledge-based understanding; left ventricular wall motion; normal ventricles; pathological ventricles; quantitative analysis; regional shape; rule-based scheme; statistical analysis; Area measurement; Cardiology; Fuzzy logic; Knowledge engineering; Medical expert systems; Motion analysis; Pathology; Shape; Size measurement; Solid modeling;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Computers in Cardiology 1989, Proceedings.
  • Conference_Location
    Jerusalem
  • Print_ISBN
    0-8186-2114-1
  • Type

    conf

  • DOI
    10.1109/CIC.1989.130600
  • Filename
    130600