DocumentCode
3083645
Title
Design and analysis of shunt hybrid filter control topology for mitigation of load current harmonics
Author
Suresh, Smitha ; Devarajan, Narayanasamy ; Rajasekaran, V.
Author_Institution
Kalaignar Karunanidhi Inst. of Technol., Coimbatore, India
fYear
2012
fDate
7-9 Dec. 2012
Firstpage
1189
Lastpage
1193
Abstract
The hybrid approach of active and passive filter combination is used to eliminate the harmonics in non-linear load is presented in this paper. The objective of the proposed work is to mainly concentrate on reduction of load current harmonics and power factor improvement. The active filter is used to eliminate low order high amplitude harmonics, which is not an economic solution. Even though the passive filters are accepted as cost-effective solution, there is a chance for occurrence of resonance in the system. In this condition, the combination of filters may help to improve filtering characteristics. This strategy improves the passive filter compensation characteristics without depending on the system impedance and avoiding the resonance problem. The combined hybrid filter is designed and simulated in MATLAB/Simulink environment. The performance is analyzed, compared with various conditions, and results are presented.
Keywords
active filters; passive filters; power factor correction; power harmonic filters; resonance; active filter; load current harmonics mitigation; nonlinear load; passive filter compensation; power factor improvement; resonance; shunt hybrid filter control topology; Active filters; Harmonic analysis; Hybrid power systems; Passive filters; Power filters; Power harmonic filters; Power Factor Improvement; Power Quality; Shunt Hybrid Filter (SHF); Space Vector Pulse Width Modulation (SVPWM); Total Harmonic Distortion (THD); VSC Inverters;
fLanguage
English
Publisher
ieee
Conference_Titel
India Conference (INDICON), 2012 Annual IEEE
Conference_Location
Kochi
Print_ISBN
978-1-4673-2270-6
Type
conf
DOI
10.1109/INDCON.2012.6420798