DocumentCode :
3094869
Title :
Measurement Bias Detection, Identification and Elimination for Multi-Zone Thermal Processing in Semiconductor Manufacturing
Author :
Weng Khuen Ho ; Romagnoli, J.A. ; Keck Voon Ling
Author_Institution :
Nat. Univ. of Singapore, Singapore
fYear :
2007
fDate :
5-8 Nov. 2007
Firstpage :
2678
Lastpage :
2682
Abstract :
Temperature uniformity within wafer and from wafer to wafer are important issues with stringent specifications and significant impact on the smallest feature size or critical dimension. To obtain temperature uniformity, a wafer is heated by multiple independently controlled heating elements simultaneously. The accuracy of temperature measurement is an issue. Faults include sensor bias, complete failure, drifting, precision degradation etc. In this paper, we demonstrate the detection of gross errors and the elimination of biased reading in a multi-zone thermal system for semiconductor wafer processing.
Keywords :
semiconductor device manufacture; bias detection measurement; gross errors detection; multizone thermal processing; semiconductor manufacturing; semiconductor wafer processing; temperature measurement; temperature uniformity; Chemical technology; Heating; Manufacturing processes; Semiconductor device manufacture; Semiconductor device modeling; Temperature control; Temperature distribution; Temperature measurement; Temperature sensors; Thermal resistance;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Industrial Electronics Society, 2007. IECON 2007. 33rd Annual Conference of the IEEE
Conference_Location :
Taipei
ISSN :
1553-572X
Print_ISBN :
1-4244-0783-4
Type :
conf
DOI :
10.1109/IECON.2007.4459962
Filename :
4459962
Link To Document :
بازگشت