    The paper presents novel control system for shunt active power filter (APF) connected to an electrical grid via LCL circuit. Such a circuit constitutes 3rd order low pass filter and almost completely attenuates current ripples from PWM, which are the major drawback of APF connected via inductors. Such a solution requires control that overcomes LCL resonance problem and, at the same time, maximizes control dynamics. The presented control system is fully predictive and provides control dynamics which is limited only by circuit parameters. The control has been implemented in high power, 1.2 MVA APF system. The paper includes both simulations and experimental results.
  • Keywords
    active filters; low-pass filters; power grids; power harmonic filters; power system interconnection; pulse width modulation; LCL circuit; PWM; electrical grid; low pass filter; predictive control; shunt active power filter; Active filters; Control systems; Frequency domain analysis; Harmonic analysis; Passive filters; Power filters; Power harmonic filters;