    MR-compatible ultrasound research platform for motion tracking to reduce motion induced artifacts in MR imaging

  • Author

    Tretbar, S.H. ; Hewener, Holger J. ; Speicher, Daniel ; Barthscherer, Tobias ; Bongers, Andre ; Jenne, Jurgen W. ; Gunther, M.

  • Author_Institution
    Dept. Ultrasound, Fraunhofer IBMT, St. Ingbert, Germany
  • fYear
    2013
  • fDate
    21-25 July 2013
  • Firstpage
    553
  • Lastpage
    556
  • Abstract
    High resolution or time consuming MR-imaging methods suffer from motion artifacts due to breathing or cardiac motion. This has an impact on high resolution morphological images and increasingly on highly sensitive functional MRI. MR-inherent compensation techniques like navigator echoes and methods like ECG or respiratory gating can reduce these artifacts but are indirect methods monitoring surrogates and not very reliable indicating the actual organ positions. To improve MR imaging of moving organs we propose diagnostic ultrasound (US) as additional imaging method for organ motion detection and compensation during MRI scanning. We developed an MRI compatible US platform to enable non-invasive hybrid MR-US-imaging and real-time US-motion compensation. The ultrasound system and the transducers have to be insensitive to the high electromagnetic fields like we find them outside and inside the tomograph and they may not interfere with the MR-system electromagnetically. In this work, our US research platform and special ultrasound transducers are presented that meet these requirements consisting of the beamformer unit, a special LCD display for use close to the MR-magnet, special ultrasound probes (T-shaped 2×64 element phased array transducers) and a separate PC to be used in the control room of the MRI scanner. The system can use multiple transducers in parallel mode to acquire up to 4 US images simultaneously. Tracking of moving structures in the ultrasound images is performed by a stochastic tracking algorithm, which fits a contour to the ultrasound data using affine transformations in real-time. Interferences of the US system with the MR scanner were measured and characterized. It was possible to make simultaneous measurements (US and MRI) next to and inside the MRT system to reconstruct US motion compensated MR volumes. The interferences in the ultrasound imaging induced by the MRT system can be neglected. The effects of EMC emissions by the US device on t- e MRT system are measured and characterized. Data acquisition was done in parallel to the MRI scan of organ movements inside the body. The setup was tested in a 1.5 T and a 3 T MRI systems and first ultrasound compensated MR volumes were acquired.
  • Keywords
    biological organs; biomedical MRI; biomedical transducers; biomedical ultrasonics; data acquisition; image reconstruction; image resolution; medical image processing; motion compensation; pneumodynamics; stochastic processes; ultrasonic imaging; ultrasonic transducers; ECG; T-shaped 2x64 element phased array transducers; affine transformations; beamformer unit; breathing; cardiac motion; data acquisition; diagnostic ultrasound; electromagnetic fields; high resolution MRI; high resolution morphological images; highly sensitive functional MRI; magnetic flux density 1.5 T; magnetic flux density 3 T; magnetic resonance imaging-compatible ultrasound research platform; motion induced artifact reduction; motion tracking; navigator echoes; organ motion detection; real-time ultrasound-motion compensation; respiratory gating; special LCD display; stochastic tracking algorithm; surrogate monitoring; time consuming MRI; tomography; ultrasonic motion compensated magnetic resonance volume reconstruction; ultrasound probes; ultrasound transducers; Biomedical imaging; Magnetic resonance imaging; Software; Ultrasonic imaging; Ultrasonic variables measurement; Volume measurement; MRI compatible; Motion Compensation; Ultrasound beamformer; ultrasound research interface;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium (IUS), 2013 IEEE International
  • Conference_Location
    Prague
  • ISSN
    1948-5719
  • Print_ISBN
    978-1-4673-5684-8
  • Type

    conf

  • DOI
    10.1109/ULTSYM.2013.0143
  • Filename
    6725246