DocumentCode :
3116669
Title :
Influence of multiphysics couplings on the performance of a MEMS magnetometer
Author :
Ranvier, S. ; Paquay, S. ; Requier, S. ; Lamy, H. ; Rochus, V. ; Francis, L.A. ; Rochus, P.
Author_Institution :
Belgian Inst. for Space Aeronomy, Belgium
fYear :
2011
fDate :
18-20 April 2011
Firstpage :
42375
Lastpage :
42527
Abstract :
In this paper, several physical phenomena that are usually not taken into account in MEMS simulations are considered for the simulation of a MEMS xylophone bar magnetometer. These phenomena are the temperature dependency of the material properties, the strong coupling between various fields of physics (thermal, electric and mechanical) and the stress produced by the change of temperature inside the structure. It is shown that the temperature dependency of the material properties has a relatively small influence whereas the pre-stress has a significant one. Because of the pre-stressed state, the deformation of the bar at the fundamental frequency is not a typical first mode vibration but it exhibits additional waves between the linkages, where the bar is stressed, which significantly decrease the amplitude of the deflection.
Keywords :
deformation; magnetometers; microsensors; vibrations; MEMS xylophone bar magnetometer; first mode vibration; multiphysics couplings; temperature dependency; Electrokinetics; Magnetic properties; Magnetic separation; Magnetomechanical effects; Magnetometers; Micromechanical devices; Stress;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Thermal, Mechanical and Multi-Physics Simulation and Experiments in Microelectronics and Microsystems (EuroSimE), 2011 12th International Conference on
Conference_Location :
Linz
Print_ISBN :
978-1-4577-0107-8
Type :
conf
DOI :
10.1109/ESIME.2011.5765803
Filename :
5765803
Link To Document :
بازگشت