Comparison of Step Length Estimators from Weareable Accelerometer Devices
Author :
Alvarez, Diego ; Gonzalez, Rafael C. ; Lopez, Antonio ; Alvarez, Juan C.
Author_Institution :
Electr. Eng. Dept., Oviedo Univ., Gijon
fYear :
2006
fDate :
Aug. 30 2006-Sept. 3 2006
Firstpage :
5964
Lastpage :
5967
Abstract :
Wearable accelerometry provides easily portable systems that supply real-time data adequate for gait analysis. When they do not provide direct measurement of a spatio-temporal parameter of interest, such as step length, it has to be estimated with a mathematical model from indirect sensor measurements. In this work we are concerned with the accelerometry-based estimation of the step length in straight line human walking. We compare five step length estimators. Measurements were taken from a group of four adult men, adding up a total of 800 m per individual of walking data. Also modifications to these estimators are proposed, based on biomechanical considerations. Results show that this modifications lead to improvements of interest over previous methods
Keywords :
accelerometers; biomedical equipment; biomedical measurement; gait analysis; portable instruments; accelerometry-based step length estimation; biomechanics; gait analysis; human walking; indirect sensor measurement; mathematical model; portable system; real-time data; spatiotemporal parameter; step length estimators; wearable accelerometer devices; Accelerometers; Cities and towns; Data acquisition; Force measurement; Humans; Legged locomotion; Length measurement; Mathematical model; Real time systems; Spine;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society, 2006. EMBS '06. 28th Annual International Conference of the IEEE
Conference_Location :
New York, NY
ISSN :
1557-170X
Print_ISBN :
1-4244-0032-5
Electronic_ISBN :
1557-170X
Type :
conf
DOI :
10.1109/IEMBS.2006.259593
Filename :
4463166
Link To Document :
بازگشت