Abstract
This paper investigates the influence of some parameters on the cogging torque developed by directly driven permanent magnet synchronous wind generators. It is shown that many parameters have the influence on cogging torque and the slot and pole number combination has a significant effect on cogging torque. A simple factor has been introduced to indicate the effect of the slot and pole number combination. The simulation and experiment results verify the effect of the proposed method.
Keywords
permanent magnet generators; synchronous generators; torque; wind power plants; cogging torque; directly driven permanent magnet synchronous wind generator; electric machine design; Forging; Magnetic noise; Magnetic resonance; Magnetostatics; Permanent magnets; Synchronous generators; Torque; Wind energy; Wind power generation; Wind turbines; cogging torque; electric machine design; permanent magnet; synchronous generator;