Abstract :
This paper is aimed at the influence of the linear non uniformity of pollution layer on critical flashover voltage Vcri of polluted insulator under lightning impulse voltage. It is shown that the experimental values of Vcri depends on the configuration of pollution and the polarity of voltage. A mathematical model enabling to compute the flashover discharge characteristic constants (n and N) and the critical thickness of pollution layer and thence the critical flashover voltage is presented. It´s also shown that n and N are not static and they depend on the parameters of the equivalent electrical circuit, thermal characteristics of discharge and the condition of propagation. The computed critical voltages are found in a good accordance with the experimental ones.
Keywords :
flashover; insulators; flashover discharge characteristic constants; flashover voltage; insulator flashover; lightning impulse voltage; polluted insulator; pollution thickness; Conductivity; Discharges; Electrodes; Flashover; Insulators; Pollution; Resistance;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
High Voltage Engineering and Application (ICHVE), 2010 International Conference on
Conference_Location :
New Orleans, LA
Print_ISBN :
978-1-4244-8283-2
Type :
conf
DOI :
10.1109/ICHVE.2010.5640711
Filename :
5640711
Link To Document :
بازگشت