  • Abstract
    This paper deals with harmonics control of a 20 MVA PWM inverter-fed LSM drive system for the Yamanashi Maglev Test Line in Japan. Contents include: (1) maintaining current control performance and compensating the resonant characteristics of the LSM load with a high-power filter; (2) developing a novel PWM control method, in order to reduce the lowest and/or second order carrier harmonics caused by asymmetrical PWM multiplication; and (3) reducing the inductive interference caused by zero sequence harmonics with a common-mode reactor
  • Keywords
    DC-AC power convertors; PWM invertors; compensation; harmonic distortion; linear synchronous motors; magnetic levitation; power filters; power system harmonics; railways; synchronous motor drives; thyristor convertors; 20 MVA; Japan; PWM inverter; Yamanashi Maglev Test Line; asymmetrical PWM multiplication; common-mode reactor; current control performance; harmonics control; high-power filter; inductive interference; linear synchronous motor drives; resonant characteristics compensation; zero sequence harmonics; Control systems; Current control; Inductors; Interference; Magnetic levitation; Power harmonic filters; Pulse width modulation; Pulse width modulation inverters; Resonance; System testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Conversion Conference - Nagaoka 1997., Proceedings of the
  • Conference_Location
    Nagaoka
  • Print_ISBN
    0-7803-3823-5
  • Type

    conf

  • DOI
    10.1109/PCCON.1997.645583
  • Filename
    645583