DocumentCode :
3194535
Title :
Non-intrusive measurement of GIS barrier surface charging
Author :
Wang, C.X.
Author_Institution :
Nat. Grid Res. & Dev. Centre, Leatherhead, UK
fYear :
1995
fDate :
22-25 Oct 1995
Firstpage :
420
Lastpage :
423
Abstract :
Recently obtained results from both on-site measurement and laboratory investigations have conclusively shown that surface charging of insulators in an ac gas insulated substation (GIS) can lead to flashovers. Although it has been recognised that prevention of charge accumulation on insulators is crucial for dc GIS design, many normal operations in an ac GIS result in sections being isolated with standing trapped charges on the busbars. Under such situations, an ac GIS sustains dc stresses just like a dc GIS. This means that insulators in an ac GIS can also suffer from electric charging and the associated problems. This paper offers an outline and some preliminary results of diagnostic techniques based upon detecting electric field flux emanating from unshielded barrier rims
Keywords :
gas insulated substations; insulation testing; surface charging; AC gas insulated substation; GIS barrier surface charging; busbars; diagnostic techniques; electric field flux; flashover; insulators; nonintrusive measurement; Charge measurement; Current measurement; Flashover; Gas insulation; Geographic Information Systems; Laboratories; Partial discharges; Stress; Substations; Surface charging;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Insulation and Dielectric Phenomena, 1995. Annual Report., Conference on
Conference_Location :
Virginia Beach, VA
Print_ISBN :
0-7803-2931-7
Type :
conf
DOI :
10.1109/CEIDP.1995.483752
Filename :
483752
Link To Document :
بازگشت