DocumentCode :
3196216
Title :
Tevatron Beam Position Monitor Upgrade
Author :
Wolbers, S. ; Banerjee, B. ; Barker, B. ; Bledsoe, S. ; Boes, T. ; Bowden, M. ; Cancelo, G. ; Forster, B. ; Duerling, G. ; Haynes, B. ; Hendricks, B. ; Kasza, T. ; Kutschke, R. ; Mahlum, R. ; Martens, M. ; Mengel, M. ; Olson, Magnus ; Pavlicek, Vladimir ;
Author_Institution :
Fermilab, Batavia, IL
fYear :
2005
fDate :
16-20 May 2005
Firstpage :
410
Lastpage :
412
Abstract :
The Tevatron Beam Position Monitor (BPM) readout electronics and software have been upgraded to improve measurement precision, functionality and reliability. The original system, designed and built in the early 1980’ s, became inadequate for current and future operations of the Tevatron. The upgraded system consists of 960 channels of new electronics to process analog signals from 240 BPMs, new front-end software, new online and controls software, and modified applications to take advantage of the improved measurements and support the new functionality. The new system reads signals from both ends of the existing directional stripline pickups to provide simultaneous proton and antiproton position measurements. Measurements using the new system are presented that demonstrate its improved resolution and overall performance.
Keywords :
Application software; Control systems; Monitoring; Position measurement; Protons; Readout electronics; Signal processing; Signal resolution; Software measurement; Stripline;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Particle Accelerator Conference, 2005. PAC 2005. Proceedings of the
Print_ISBN :
0-7803-8859-3
Type :
conf
DOI :
10.1109/PAC.2005.1590451
Filename :
1590451
Link To Document :
بازگشت