• DocumentCode
    3202009
  • Title

    Uniform Irradiation Systems Using A Rotatable Stage for Test Facilities of PEFP

  • Author

    Park, B.S. ; Lee, S.K. ; Kim, K.R. ; Choi, B.H.

  • Author_Institution
    KAERI, Daejeon, Korea
  • fYear
    2005
  • fDate
    16-20 May 2005
  • Firstpage
    1383
  • Lastpage
    1385
  • Abstract
    A new irradiation facility has been developed using not only electric magnets but also a rotatable stage. Generally, the scanning method using magnets has been widely used in most of facilities. However, in this study another new methods have been developed: Two scanning method using a rotatable stage have been proved to make uniform irradiation-as large as 20 cm in diameter with more than 90% uniformity. The mechanical wobbler system makes the same effect as the wobbler system. And the beam is swept along the spiral path with a fixed and variable angular frequency during the scanning in the spiral scanning system.
  • Keywords
    Aluminum; Degradation; Frequency; Magnets; Monitoring; Particle beams; Particle scattering; Spirals; Test facilities; Trajectory;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 2005. PAC 2005. Proceedings of the
  • Print_ISBN
    0-7803-8859-3
  • Type

    conf

  • DOI
    10.1109/PAC.2005.1590769
  • Filename
    1590769