Title :
Beam Orbit Diagnostics and Control in Candle Storage Ring
Author :
Amatuni, G. ; Vardanyan, A. ; Martirosyan, Y. ; Mikaelyan, R. ; Tsakanov, V.
Author_Institution :
CANDLE, Yerevan, 375040, Armenia, gayane@asls.candle.am
Abstract :
Stability requirements for the CANDLE light source are the consequence of a small electron beam size and a tolerable photon beam parameters. In a real machine, the components of the storage ring have static and dynamic imperfections, which cause disturbance of the electron beam and consequently photon beams parameters. In the present paper the basic approaches to the beam diagnostics, control and correction issues for the CANDLE facility are given. The algorithms, electronics and processing hardware are described.
Keywords :
Current measurement; Electron beams; Energy measurement; Extraterrestrial measurements; Feedback; Lattices; Loss measurement; Magnets; Position measurement; Storage rings;
Conference_Titel :
Particle Accelerator Conference, 2005. PAC 2005. Proceedings of the
Print_ISBN :
0-7803-8859-3
DOI :
10.1109/PAC.2005.1590867