  • Abstract
    The rf photocathode gun and the solenoid for the SPARC project at INFN-LNF (Frascati) have been fabricated and undergone initial testing at UCLA. The advanced aspects of the design of these devices are detailed. Final diagnosis of the tuning of the RF gun performance, including operating mode frequency and field balance, is described. The emittance compensating solenoid magnet, which is designed to be tuned in longitudinal position by differential excitation of the coils, has been measured using Hall probe scans for field profiling, and pulsed wire methods to determine the field center. Comparisons between measurements and the predictions of design codes are made.