• DocumentCode
    3213271
  • Title

    The Optimization of the Electron Injector Resonant System Based on the Evanescent Oscillations

  • Author

    Ayzatsky, M.I. ; Kramarenko, K.Yu. ; Kushnir, V.A. ; Mytrochenko, V.V. ; Zhiglo, V.Ph. ; Perezhogin, S.A.

  • Author_Institution
    NSC KIPT, Kharkov, 61108, Ukraine
  • fYear
    2005
  • fDate
    16-20 May 2005
  • Firstpage
    3170
  • Lastpage
    3172
  • Abstract
    The methods and results of the bunching system optimization in the compact S – band electron injector are presented in the report. The injector consists of the low-voltage diode electron gun and bunching system based on the resonant system with the evanescent oscillations. In the bunching system such field distribution along the axis is realized, that its amplitude increases from the point of injection of electrons to the exit. The optimized resonance system allows to obtain the electron bunches with the phase length less than 10° (for 70 % particles) at the injector exit.
  • Keywords
    Apertures; Diodes; Electrodynamics; Electron accelerators; Frequency; Geometry; Optical coupling; Optimization methods; Resonance; Space charge;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 2005. PAC 2005. Proceedings of the
  • Print_ISBN
    0-7803-8859-3
  • Type

    conf

  • DOI
    10.1109/PAC.2005.1591402
  • Filename
    1591402