• DocumentCode
    3216144
  • Title

    Calculating of Coupling Factor of Microwave Electron Gun

  • Author

    Xiao-Hao, Bian ; Huai-Bi, Chen ; Shu-Xin, Zheng ; Li, Derun

  • Author_Institution
    Tsinghua University, Beijing, 100084, China
  • fYear
    2005
  • fDate
    16-20 May 2005
  • Firstpage
    3656
  • Lastpage
    3658
  • Abstract
    To design the coupler of a designing microwave electron gun, we use “energy method” proposed by Derun Li, et al. The intrinsic Q of the electron gun cavity is very high: about 20000. The method is to calculate the intrinsic and external Q values of a cavity coupled to a waveguide, using MAFIA code in time domain. The comparisons between simulation and experimental results are given for a set of different coupling lengths. The result shows that “energy method” works efficiently for high Q cavities.
  • Keywords
    Attenuation; Cathodes; Costs; Cyclotrons; Electron accelerators; Frequency domain analysis; Iris; Microwave theory and techniques; Numerical simulation; Steady-state;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 2005. PAC 2005. Proceedings of the
  • Print_ISBN
    0-7803-8859-3
  • Type

    conf

  • DOI
    10.1109/PAC.2005.1591571
  • Filename
    1591571