• DocumentCode
    3229103
  • Title

    Measurement of the added specular reflection attenuation by using a grooved bottom surface in the backing of CMUTs

  • Author

    Chapagain, Kamal Raj ; Rønnekleiv, Arne

  • Author_Institution
    Norwegian Univ. of Sci. & Technol., Trondheim, Norway
  • fYear
    2011
  • fDate
    18-21 Oct. 2011
  • Firstpage
    1004
  • Lastpage
    1007
  • Abstract
    The backing structure mostly used in Capacitive Micro machined Ultrasonic Transducers (CMUTs) is a composite of epoxy and tungsten powder. To be able to absorb the acoustic signals, it should have high acoustic impedance that matches with the silicon substrate (on which CMUTs are manufactured) and it should be lossy. If we are able to make this structure thick enough, then it will damp out the signal in the backing so that it would not reflect back to the transducer. But if we intend to use the transducer in applications where there is no room for the thick backing, for example in IVUS (Intra vascular Ultrasound), a groove structured backing could be used. The grooves give extra attenuation by scattering the waves in other directions so that a thinner backing would be enough. The scattering removes power from the specular reflection from the back surface. This reflection is otherwise harmful for the imaging. In this paper, we will present how to make such a structure. Moreover, we will present some experimental results to show that this type of structure reduces the specular reflection and compare the obtained results with theoretical calculations. It is shown that the desired reflection level for a medical imaging application, estimated to be about 20 dB for CMUTs at the top of the backing, is obtained over a wide range of frequencies around 20 MHz using an absorber thickness of 200 μm.
  • Keywords
    ultrasonic transducers; CMUT; acoustic impedance; acoustic signal; added specular reflection attenuation; backing structure; capacitive micro machined ultrasonic transducers; epoxy; groove structured backing; grooved bottom surface; intra vascular ultrasound; medical imaging application; silicon substrate; thinner backing; tungsten powder; Acoustic measurements; Acoustics; Attenuation; Silicon; Surface impedance; Transducers; Tungsten;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium (IUS), 2011 IEEE International
  • Conference_Location
    Orlando, FL
  • ISSN
    1948-5719
  • Print_ISBN
    978-1-4577-1253-1
  • Type

    conf

  • DOI
    10.1109/ULTSYM.2011.0246
  • Filename
    6293366