DocumentCode
323208
Title
C-SPRINT: a prototype Compton camera system for low energy gamma ray imaging
Author
LeBlanc, J.W. ; Clinthorne, N.H. ; Hua, C.-H. ; Nygård, E. ; Rogers, W.L. ; Wehe, D.K. ; Weilhammer, P. ; Wilderman, S.J.
Author_Institution
Dept. of Nucl. Eng., Michigan Univ., Ann Arbor, MI, USA
fYear
1997
fDate
9-15 Nov 1997
Firstpage
357
Abstract
An electronically-collimated imaging system is being built using pixellated, low-noise, position-sensitive silicon as the first detector, and a sodium iodide scintillation detector ring as the second detector. The system consists of a single 3×3×0.1 cm3 silicon pad detector module with 1 keV FWHM (noise-limited) energy resolution centered at the front face of a 50 cm diameter, 10 cm long NaI detector annulus. Custom acquisition and timing electronics have been manufactured to minimize system dead time. Monte Carlo modeling is used to predict system sensitivity and position resolution. Simulations using the existing setup show angular uncertainties of 4.1° and 2.1° FWHM for 99mTc and 131I point sources, respectively (7.2 mm and 3.7 mm at 10 cm). Sensitivity can be improved by more than a factor of a hundred over the existing setup by stacking five 1 mm thick 9×9 cm2 silicon arrays and redesigning the second detector geometry to accept a wider range of scattering angles. Lower bound calculations show that our electronically-collimated camera system challenges current mechanically-collimated systems for both 99mTc and 131I despite the deleterious effects of Doppler broadening. Preliminary measurements show a timing resolution of 41 ns FWHM between the silicon detector and a single SPRINT module
Keywords
Compton effect; Doppler broadening; Monte Carlo methods; cameras; data acquisition; gamma-ray detection; nuclear electronics; position sensitive particle detectors; silicon radiation detectors; solid scintillation detectors; timing circuits; 0.1 cm; 10 cm; 3 cm; 50 cm; 131I; 99mTc; C-SPRINT; Doppler broadening; I; Monte Carlo modeling; NaI; Si; Tc; acquisition electronics; electronically-collimated imaging system; low energy gamma ray imaging; lower bound calculations; pixellated low-noise position-sensitive detector; prototype Compton camera system; scintillation detector; timing electronics; Cameras; Energy resolution; Face detection; Optical imaging; Pixel; Position sensitive particle detectors; Prototypes; Silicon; Solid scintillation detectors; Timing;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium, 1997. IEEE
Conference_Location
Albuquerque, NM
ISSN
1082-3654
Print_ISBN
0-7803-4258-5
Type
conf
DOI
10.1109/NSSMIC.1997.672602
Filename
672602