• DocumentCode
    323674
  • Title

    Practical problems of data collection and interpretation for large scale automated ultrasonic inspections

  • Author

    Stansfield, A.M.

  • fYear
    1994
  • fDate
    34445
  • Firstpage
    42370
  • Lastpage
    42372
  • Abstract
    The inspection techniques are nearly all automated ultrasonic inspections and are being performed using the MIPS/GUIDE inspection software systems developed by Nuclear Electric at the NDT Applications Centre in Manchester. This pre-service inspection is the most comprehensive automated inspection of any PWR constructed to date. This paper looks at the developments to the software that were required for the inspection and some of the problems that the inspection presented. MIPS and GUIDE are two complementary software packages for carrying out and analysing the data from automated ultrasonic inspections
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Advanced Techniques for Collection and Interpretation of NDT Data (Digest No. 1994/102), IEE Colloquium on
  • Conference_Location
    London
  • Type

    conf

  • Filename
    674852