• DocumentCode
    3237653
  • Title

    RITS-3 self-break water switch maintenance

  • Author

    Puetz, E. ; Portillo, S. ; Hahn, K. ; Molina, I. ; Cordova, S. ; Maenchen, J. ; Johnson, D.L. ; Gignac, R. ; Wilkins, F.

  • Author_Institution
    Sandia Nat. Lab., Albuquerque, NM, USA
  • fYear
    2004
  • fDate
    23-26 May 2004
  • Firstpage
    421
  • Lastpage
    423
  • Abstract
    The radiographic integrated test stand (RITS-3) is a 5-MV, 160-kA, 70-ns inductive voltage adder accelerator at Sandia National Laboratories used to develop critical understanding of x-ray sources and flash radiographic drivers. On RITS-3 three pulse forming lines (PFLs) are used to drive three inductive voltage adder cavities. Each PFL contains a fast-pulse-charged, self-breakdown annular water switch that is used for initial pulse shaping and timing. Low loss in the switches combined with good synchronization is required for efficient operation of the accelerator. Switch maintenance is closely monitored over time to determine the effects of wear on switch breakdown performance.
  • Keywords
    maintenance engineering; pulse shaping; pulsed power switches; radiography; 160 kA; 5 MV; 70 ns; Sandia National Laboratories; annular water switch; fast-pulse-charged water switch; flash radiographic drivers; inductive voltage adder accelerator; inductive voltage adder cavities; pulse forming lines; radiographic integrated test stand; self-break water switch maintenance; switch breakdown performance; synchronization; x-ray sources; Electric breakdown; Laboratories; Life estimation; Monitoring; Pulse shaping methods; Radiography; Switches; Testing; Timing; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Modulator Symposium, 2004 and 2004 High-Voltage Workshop. Conference Record of the Twenty-Sixth International
  • Print_ISBN
    0-7803-8586-1
  • Type

    conf

  • DOI
    10.1109/MODSYM.2004.1433602
  • Filename
    1433602