DocumentCode
32424
Title
A novel generator for high-voltage bipolar square pulses with applications in sterilization of microorganism
Author
Xiong Lan ; Ma Long ; Xie Zi-jie ; Xin Qin ; Zhang De-qing ; Yang Zi-kang
Author_Institution
State Key Lab. of Power Transm. Equip. & Syst. Security & New Technol., Chongqing Univ., Chongqing, China
Volume
22
Issue
4
fYear
2015
fDate
Aug-15
Firstpage
1887
Lastpage
1895
Abstract
In this paper, we propose and design a novel generator for the high voltage square pulses with the changeable polarities in order to reach the requirements and the needs for the intended experiments on sterilization of microorganism. The major component of our circuits is a non-trivial combination between a half bridge Marx generator and an H bridge in series, combining with the DSP control unit, which can adjust the voltages, frequencies, pulse widths and polarities, and also tolerate various loads. More precisely, we illustrate the design and operation principles for each module in the constructed circuit and analyze the system performance with various loads. The effectiveness and correctness of our proposed circuit and methodologies have been verified and demonstrated by both PSIM simulation results and our own prototype. In this paper, we also show the stability and reliability of the pulse generator we proposed in terms of various load conditions and operation safety respectively. Furthermore, we also observe that the key parameters based on our constructed pulse generator can be easily adjusted which include voltages, frequencies, pulse widths and polarities. We hope that our work will stimulate the further investigations on design and analysis of pulse generators with a focus on modularization and miniaturization.
Keywords
bridge circuits; circuit reliability; circuit stability; microorganisms; pulse generators; pulsed power supplies; sterilisation (microbiological); DSP control unit; H bridge; PSIM simulation; half bridge Marx generator stability; high-voltage bipolar square pulse generator reliability; microorganism sterilization; miniaturization; modularization; pulse generator operation safety; Bridge circuits; Capacitors; Discharges (electric); Generators; Inductors; Microorganisms; Switches; Bipolar; H bridge; Marx generator; Rising edge; Square pulse;
fLanguage
English
Journal_Title
Dielectrics and Electrical Insulation, IEEE Transactions on
Publisher
ieee
ISSN
1070-9878
Type
jour
DOI
10.1109/TDEI.2014.004805
Filename
7179145
Link To Document