DocumentCode
3248909
Title
Analysis of Partial Discharge Using Non-Linear Clustering Algorism
Author
Kim, Tag-Yong ; Sin, Hyun-Taek ; Lee, Jong-Yong ; Yeon, Kyu-Ho ; Lee, Chung-Ho ; Hong, Jin-woong
Author_Institution
Dept. of Electr. Eng., Kwangwoon Univ., Seoul
fYear
2006
fDate
38869
Firstpage
502
Lastpage
505
Abstract
In this paper, we examine discharge characteristics of cross-linked polyethylene (since then; XLPE) according to void. Voltage was applied to power frequency by step method, and calibration of discharge was set to 50[pC] (slope=8.333). After the voltage was applied, for 10 [sec] (600 [cycle]), occurring discharge and number were detected. Determine of input pattern is difficult because discharge pattern is irregular. Therefore we investigated phi-q-n pattern using the clustering method, and investigated variation of center vector and cluster member
Keywords
XLPE insulation; calibration; partial discharge measurement; pattern clustering; power engineering computing; XLPE; calibration; clustering method; cross-linked polyethylene; discharge characteristics; nonlinear clustering algorithm; partial discharge analysis; power frequency; Cable insulation; Calibration; Clustering methods; Degradation; Dielectrics and electrical insulation; Electrodes; Frequency; Partial discharges; Trees - insulation; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Properties and applications of Dielectric Materials, 2006. 8th International Conference on
Conference_Location
Bali
Print_ISBN
1-4244-0189-5
Electronic_ISBN
1-4244-0190-9
Type
conf
DOI
10.1109/ICPADM.2006.284225
Filename
4062714
Link To Document