• DocumentCode
    3249737
  • Title

    Flux-linkage characteristics of switched reluctance motor

  • Author

    Ramanarayanan, V. ; Venkatesha, L. ; Panda, Debiprasad

  • Author_Institution
    Dept. of Electr. Eng., Indian Inst. of Sci., Bangalore, India
  • Volume
    1
  • fYear
    1996
  • fDate
    8-11 Jan 1996
  • Firstpage
    281
  • Abstract
    An important requirement in the modelling of switched reluctance motors (SRM) is the knowledge of their flux-linkage characteristics. Idealisation of the flux-linkage characteristics will result in a model which cannot predict the performance of the machine with sufficient accuracy. It is necessary therefore to determine flux-linkage characteristics as closely as possible. In this paper, a method of finding the flux-linkage characteristics is explained. The same method is demonstrated on a commercially available 4 kW, 8/6 pole OULTON SRM. The validity of the test results is checked by computing the static torque characteristics based on the measured flux-linkage characteristics and comparing them with experimentally measured static torque characteristics. The sources of measurement error are discussed
  • Keywords
    machine testing; machine theory; magnetic flux; reluctance motors; switching circuits; 4 kW; OULTON SRM; accuracy; flux-linkage characteristics; measurement error; performance modelling; static torque characteristics; switched reluctance motor; test results; Magnetic circuits; Predictive models; Reluctance machines; Reluctance motors; Rotors; Sensor phenomena and characterization; Stators; Testing; Torque measurement; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics, Drives and Energy Systems for Industrial Growth, 1996., Proceedings of the 1996 International Conference on
  • Conference_Location
    New Delhi
  • Print_ISBN
    0-7803-2795-0
  • Type

    conf

  • DOI
    10.1109/PEDES.1996.539553
  • Filename
    539553