• DocumentCode
    324975
  • Title

    Monte Carlo prompt dose calculations for the National Ignition Facility

  • Author

    Latkowski, J.F. ; Phillips, T.W.

  • Author_Institution
    Lawrence Livermore Nat. Lab., CA, USA
  • Volume
    1
  • fYear
    1997
  • fDate
    6-10 Oct 1997
  • Firstpage
    149
  • Abstract
    During peak operation, the National Ignition Facility (NIF) will conduct as many as 600 experiments per year and attain deuterium-tritium fusion yields as high as 1200 MJ/yr. The radiation effective dose equivalent (EDE) to workers is limited to an average of 0.3 mSv/yr (30 mrem/yr) in occupied areas of the facility. Laboratory personnel located outside-the facility will receive EDEs ⩽0.5 mSv/yr (⩽50 mrem/yr). The total annual occupational EDE for the facility will be maintained at ⩽0.1 person-Sv/yr (⩽10 person-rem/yr). To ensure that prompt EDEs meet these limits, three-dimensional Monte Carlo calculations have been completed
  • Keywords
    Monte Carlo methods; dosimetry; fusion reactor safety; Monte Carlo; National Ignition Facility; effective dose equivalent; laboratory personnel; prompt dose calculations; workers; Environmental management; Geometry; Ignition; Laboratories; Laser fusion; Monte Carlo methods; Neutrons; Personnel; Power lasers; Safety;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Fusion Engineering, 1997. 17th IEEE/NPSS Symposium
  • Conference_Location
    San Diego, CA
  • Print_ISBN
    0-7803-4226-7
  • Type

    conf

  • DOI
    10.1109/FUSION.1997.687008
  • Filename
    687008