• DocumentCode
    32624
  • Title

    Dielectric and partial discharge investigations on high power insulated gate bipolar transistor modules

  • Author

    Arumugam, Saravanakumar ; Gorchakov, Sergey ; Schoenemann, Thomas

  • Author_Institution
    High Voltage & High Current Technol., Univ. of Rostock, Rostock, Germany
  • Volume
    22
  • Issue
    4
  • fYear
    2015
  • fDate
    Aug-15
  • Firstpage
    1997
  • Lastpage
    2007
  • Abstract
    This paper investigates on dielectric condition assessment of high power Insulated Gate Bipolar Transistor (IGBT) modules through modern dielectric and diagnostic test methods. Two groups of IGBT samples (new and aged) are selected for this purpose. The new IGBT samples are grouped as ´set-1/virgin´ and marked as ´A´, ´B´, ´C´, ´D´ and ´E´ respectively. Amongst all, a fault (electric puncture) is introduced into the sample ´E´. The samples ´A´ and ´B´ are maintained virgin while samples ´C´, ´D´ and ´E´ are subjected to partial discharge measurements as recommended by IEC60270. The samples are qualitatively ranked based on their PD level. Subsequently, the dielectric condition of each sample is measured and analyzed over a wide span and frequency. Following this, similar experiments are carried out on IGBT samples that were aged under service and their behaviour over a wide frequency is analyzed. In conclusion, the present study might provide an opportunity in improvement of diagnostic and quality control test methods that are currently exercised on IGBT modules and power conversion devices. Also, these findings enable discrimination of electrical discharges caused by IGBT modules in power conversion equipments which might help in accurate determination of their dielectric condition and reliability.
  • Keywords
    ageing; insulated gate bipolar transistors; partial discharges; power bipolar transistors; quality control; semiconductor device testing; IEC60270; IGBT modules; IGBT samples; PD level; diagnostic test method; dielectric condition assessment; dielectric discharge investigations; dielectric reliability; dielectric test method; electric puncture; electrical discharges; high power insulated gate bipolar transistor modules; partial discharge investigations; partial discharge measurements; power conversion devices; power conversion equipments; quality control test methods; Dielectrics; Discharges (electric); Fault diagnosis; Insulated gate bipolar transistors; Partial discharges; Voltage measurement; IGBT; dielectric loss factor; insulation resistance; partial discharge;
  • fLanguage
    English
  • Journal_Title
    Dielectrics and Electrical Insulation, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1070-9878
  • Type

    jour

  • DOI
    10.1109/TDEI.2015.004984
  • Filename
    7179160