DocumentCode
327246
Title
Monitoring system activity for OS-directed dynamic power management
Author
Benini, Luca ; Bogliolo, Alessandro ; Cavallucci, Stefano ; Ricco, Bruno
Author_Institution
Dipt. di Elettronica Inf. e Sistemistica, Bologna Univ., Italy
fYear
1998
fDate
10-12 Aug. 1998
Firstpage
185
Lastpage
190
Abstract
We describe a workload monitoring system that has been specifically designed for supporting dynamic power management in personal computers with tight power constraints (such as laptop or notebook computers). Our monitoring system is minimally intrusive, and has negligible impact on system activity. Moreover, it can be used both for on-line system monitoring and off-line data collection. We used our monitoring tool to collect data on the usage of system resources (disks, CPU, keyboard and mouse) for a laptop computer, under several workload conditions. Our analysis shows that resource usage is strongly resource and workload dependent, and that on-line usage monitoring capability is a critical issue of the implementation of effective power management policies.
Keywords
operating systems (computers); portable computers; resource allocation; system monitoring; OS-directed dynamic power management; dynamic power management; personal computers; power constraints; power management policies; resource usage; system resources; workload monitoring system;
fLanguage
English
Publisher
ieee
Conference_Titel
Low Power Electronics and Design, 1998. Proceedings. 1998 International Symposium on