DocumentCode
327379
Title
On turbogenerator H.V. stator winding condition assessment by the analysis of PDHD detected on phases and insulated coils after untimely failure
Author
Rabach, G. ; Contin, A. ; Razza, F. ; Visintin, Monica
Author_Institution
Dipt. di Elettrotecnica, Elettronica ed Inf., Trieste Univ., Italy
fYear
1998
fDate
22-25 Jun 1998
Firstpage
185
Lastpage
188
Abstract
The paper deals with the results of investigations performed in order to verify whether diagnostic tests, based on Partial Discharge Height Distribution (PDHD) analysis, are able to identify the causes of deterioration and to guide the repair of the insulation system of HV rotating machine stator windings. The insulation system of a turbogenerator was tested after a breakdown occurred in service. Partial Discharge (PD) measurements were performed both on the windings and on single coils. The analysis of the results of PD measurements evidenced that the breakdown was due to a defective impregnation of the winding
Keywords
insulator testing; machine insulation; machine testing; partial discharge measurement; stators; turbogenerators; HV rotating machine; PDHD measurement; breakdown; coil; failure; insulation diagnosis; partial discharge height distribution; stator winding; turbogenerator; Electric breakdown; Insulation testing; Partial discharge measurement; Partial discharges; Performance analysis; Performance evaluation; Rotating machines; Stator windings; System testing; Turbogenerators;
fLanguage
English
Publisher
ieee
Conference_Titel
Conduction and Breakdown in Solid Dielectrics, 1998. ICSD '98. Proceedings of the 1998 IEEE 6th International Conference on
Conference_Location
Vasteras
Print_ISBN
0-7803-4237-2
Type
conf
DOI
10.1109/ICSD.1998.709256
Filename
709256
Link To Document