  • Abstract
    The paper deals with the results of investigations performed in order to verify whether diagnostic tests, based on Partial Discharge Height Distribution (PDHD) analysis, are able to identify the causes of deterioration and to guide the repair of the insulation system of HV rotating machine stator windings. The insulation system of a turbogenerator was tested after a breakdown occurred in service. Partial Discharge (PD) measurements were performed both on the windings and on single coils. The analysis of the results of PD measurements evidenced that the breakdown was due to a defective impregnation of the winding
  • Keywords
    insulator testing; machine insulation; machine testing; partial discharge measurement; stators; turbogenerators; HV rotating machine; PDHD measurement; breakdown; coil; failure; insulation diagnosis; partial discharge height distribution; stator winding; turbogenerator; Electric breakdown; Insulation testing; Partial discharge measurement; Partial discharges; Performance analysis; Performance evaluation; Rotating machines; Stator windings; System testing; Turbogenerators;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Conduction and Breakdown in Solid Dielectrics, 1998. ICSD '98. Proceedings of the 1998 IEEE 6th International Conference on
  • Conference_Location
    Vasteras
  • Print_ISBN
    0-7803-4237-2
  • Type

    conf

  • DOI
    10.1109/ICSD.1998.709256
  • Filename
    709256