DocumentCode :
3302992
Title :
The development and application of transient current monitoring as part of a maintenance strategy for power station drive systems
Author :
Watson, J.F. ; Steedman, M.J. ; Sandford, J. ; Urquhart, B.
Author_Institution :
Robert Gordon Univ., Aberdeen, UK
fYear :
35886
fDate :
30 Mar-1 Apr1998
Firstpage :
75
Lastpage :
79
Abstract :
The work presented in this paper concentrates on the development of instrumentation systems to aid the detection and analysis of broken rotor bars in three-phase induction motors. However, the use of phase current analysis to monitor other faults is well documented and the instrumentation principle proposed could be easily adopted to meet these requirements
Keywords :
induction motors; application; broken rotor bars; condition monitoring; development; instrumentation systems; maintenance strategy; phase current analysis; three-phase induction motors; transient current monitoring;
fLanguage :
English
Publisher :
iet
Conference_Titel :
Power Station Maintenance - Profitability Through Reliability, 1998. First IEE/IMechE International Conference on (Conf. Publ. No. 452)
Conference_Location :
Edinburgh
ISSN :
0537-9989
Print_ISBN :
0-85296-699-7
Type :
conf
DOI :
10.1049/cp:19980065
Filename :
674047
Link To Document :
بازگشت