DocumentCode :
3305192
Title :
Bismuth-film Glassy Carbon Electrode for the Determination of Lead by Differential Pulse Stripping Voltammetric
Author :
Men, Hong ; Zhang, Shanshan ; Zhang, Ping ; Yang, Shanrang ; Xu, Zhiming
Author_Institution :
Sch. of Autom. Eng., Northeast Dianli Univ., Jilin, China
fYear :
2010
fDate :
24-25 April 2010
Firstpage :
231
Lastpage :
234
Abstract :
This paper presents a new technology using Bismuth-film to determinate lead instead of mercury film. It is proved in the experiment that, in the optimum measuring situation (when the pH is 4, deposition time is 150s, and the deposition potential is 0.8.), the lead concentration and stripping peak current shows a good linear relationship in the measuring range of 10 to 110ug/L, which is I=0.1002C+0.0539. The experimental analysis shows that the concentration of lead in tea samples is 1.667μg / g, and the recovery rate is 91.2% ~ 101.8%. It is proved that the method of bismuth film electrode is used to measure lead with advantages of convenience, speediness, sensitivity and accuracy, etc.
Keywords :
Absorption; Bismuth; Current measurement; Electrochemical processes; Electrodes; Electrokinetics; Lead; Position measurement; Spectroscopy; Time measurement; bismuth film electrode; differential pulse voltammetry; lead ion;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Machine Vision and Human-Machine Interface (MVHI), 2010 International Conference on
Conference_Location :
Kaifeng, China
Print_ISBN :
978-1-4244-6595-8
Electronic_ISBN :
978-1-4244-6596-5
Type :
conf
DOI :
10.1109/MVHI.2010.140
Filename :
5532587
Link To Document :
بازگشت