Automated verification of multileaf collimation using portal imaging
Author :
Samant, Sanjiv S. ; Zhen, Wei ; Liu, Chihray
Author_Institution :
Dept. of Radiat. Oncology, St. Jude Children´´s Res. Hosp., Memphis, TN, USA
Volume :
2
fYear :
1999
fDate :
36434
Abstract :
Advances in linear accelerator technology have led to the emergence of conformal radiotherapy, in which complex beam configurations can be utilized to maximize radiation dose to the treatment volume, while minimizing dose to adjacent critical structures. The beam configuration is optimized in terms of position, collimation and intensity in treatment planning. The adequacy of the treatment rests on the verification of the localized treatment volume with respect to the radiation beams. Verification is performed using megavoltage portal imaging on the treatment accelerator or linac. Errors affecting treatment delivery can arise either in the construction of the custom collimation, or in positioning the patient on the linac. The collimation shape is verified using edge detection with respect to a reference point defined by both a user and a user independent template method. Image registration of anatomical landmarks using Chamfer matching is used to compute positioning errors of the patient
Keywords :
dosimetry; edge detection; image matching; image registration; linear accelerators; medical image processing; planning; radiation therapy; Chamfer matching; adjacent critical structures; anatomical landmarks; automated verification; collimation; collimation shape; complex beam configurations; conformal radiotherapy; custom collimation; edge detection; image registration; intensity; linac; linear accelerator technology; localized treatment volume; megavoltage portal imaging; multileaf collimation; patient positioning; portal imaging; position; positioning errors; radiation beams; radiation dose; reference point; treatment accelerator; treatment delivery; treatment planning; treatment volume; user independent template method; Colliding beam accelerators; Collimators; Image edge detection; Linear accelerators; Linear particle accelerator; Medical treatment; Particle beams; Portals; Shape; Structural beams;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
[Engineering in Medicine and Biology, 1999. 21st Annual Conference and the 1999 Annual Fall Meetring of the Biomedical Engineering Society] BMES/EMBS Conference, 1999. Proceedings of the First Joint
Conference_Location :
Atlanta, GA
ISSN :
1094-687X
Print_ISBN :
0-7803-5674-8
Type :
conf
DOI :
10.1109/IEMBS.1999.804014
Filename :
804014
Link To Document :
بازگشت