Quantitative assessment of the effect of anode surface roughness on diagnostic X-ray spectra: A Monte Carlo simulation study
Author :
Mehranian, A. ; Ay, M.R. ; Alam, N. Riyahi ; Zaidi, H.
Author_Institution :
Dept. of Med. Phys. & Biomed. Eng., Tehran Univ. of Med. Sci., Tehran, Iran
fYear :
2009
fDate :
Oct. 24 2009-Nov. 1 2009
Firstpage :
2902
Lastpage :
2907
Abstract :
An experimental measurement study involving surface profilometry and scanning electron microscopy (SEM) combined with MCNP4C-based Monte Carlo simulations was performed to evaluate anode surface roughness in aged X-ray tubes and to quantitatively predict its impact and relevance on generated diagnostic X-ray spectra. Surface profilometry determined that the center-line average roughness in the most aged x-ray tube evaluated in our study was around 50 ?m. SEM measurements also revealed valuable details about the morphology of cracks and irregularities on the anode´s focal path. An image-based modeling method was followed for defining more realistic models from the surface-cracked anodes into MCNP´s environment. In this approach, the matrices of focal spot images were numerically processed such that the mean depth of cracks along with their spatial pattern to be incorporated into pixel values in agreement with the measured average depths. By invoking MCNP4C´s Gaussian energy broadening (GEB), the correctness of this code in simulating diagnostic x-ray spectra was well validated against experimentally-measured spectra. The simulated spectra in surface deteriorated anode models were compared with those simulated in perfectly plain anodes considered as reference. From these comparisons, an intensity loss of 4.5% and 16.8% was predicted for anodes aged by 5 and 50 ?m-deep cracks in conditions of 50 kVp, 6 degree target angle, 2.5 mm Al total filtration. By deploying several point detectors (F5 tallies) along the anode-cathode direction and averaging exposure over them, it was found that for a 12 degree anode roughened by 50 ?m-deep cracks, the reduction of overall exposure is 14.9% and 13.1% for 70 and 120 kVp tube voltages, respectively. Finally, change in patient entrance skin dose (ESD), as a result of anode roughness, was assessed under various conditions in a chest X-ray radiography examination. In conclusion, anode surface roughness can have a non negligible effe- - ct on output spectra in aged X-ray imaging tubes and as such, depending on X-ray tube´s workload, its impact should be carefully considered in medical X-ray imaging systems.
Keywords :
Monte Carlo methods; X-ray imaging; X-ray spectra; biomedical imaging; patient diagnosis; radiography; scanning electron microscopy; MCNP4C Gaussian energy broadening; Monte Carlo simulation; X-ray tube workload; aged X-ray imaging tubes; anode focal path; anode surface roughness; anode-cathode direction; center-line average roughness; chest X-ray radiography examination; diagnostic X-ray spectra; focal spot images; image-based modeling method; medical X-ray imaging systems; patient entrance skin dose; point detectors; scanning electron microscopy; spatial pattern; surface deteriorated anode models; surface profilometry; surface-cracked anodes; Aging; Anodes; Electron tubes; Performance evaluation; Rough surfaces; Scanning electron microscopy; Surface cracks; Surface morphology; Surface roughness; X-ray imaging;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record (NSS/MIC), 2009 IEEE
Conference_Location :
Orlando, FL
ISSN :
1095-7863
Print_ISBN :
978-1-4244-3961-4
Electronic_ISBN :
1095-7863
Type :
conf
DOI :
10.1109/NSSMIC.2009.5401620
Filename :
5401620
Link To Document :
بازگشت