DocumentCode
3328080
Title
Validation of GATE simulations of the 176Lu intrinsic activity in LSO detectors
Author
McIntosh, Bryan ; Goertzen, Andrew L.
Author_Institution
Dept. of Phys. & Astron., Univ. of Manitoba, Winnipeg, MB, Canada
fYear
2009
fDate
Oct. 24 2009-Nov. 1 2009
Firstpage
3426
Lastpage
3428
Abstract
The effects of the intrinsic activity of lutetium-based scintillators such as lutetium oxyorthosilicate (LSO) used in positron emission tomography (PET) imaging have been well documented and is generally not a concern in routine scanning. However, this intrinsic activity can become problematic when using a wide energy window or in low count rate scenarios such as cell trafficking studies in small animal imaging. To date, no systematic validation of Monte Carlo simulations of the intrinsic 176Lu activity has been performed, making it difficult to incorporate them into the design and simulation of proposed scanners. This study seeks to validate Geant4 Application for Tomographic Emission (GATE) simulations of the 176Lu intrinsic activity in LSO based detectors against data gathered from a pair of LSO-based Siemens Inveon detectors. Measurements from two opposing detector modules were acquired using NIM electronics and a PC based data acquisition (DAQ) card. The detectors were characterized by determining the count rate due to intrinsic coincidence events vs. detector separation while stepping the lower level discriminator (LLD). Monte Carlo simulations were performed using GATE to reproduce the geometry of the bench-top measurements made with the two detectors, modeling the intrinsic activity of the 176Lu as an ion source located within the scintillator crystals. Initial measurements show good agreement between the simulated and measured results. Intrinsic coincidence count rates are in good agreement at all distances, diverging when the LLD is stepped to a level near an intrinsic photopeak. The bench-top setup results require minor refinement to improve the accuracy of measurements at low energy levels which will be done before completing validation of the simulation results.
Keywords
Monte Carlo methods; image scanners; positron emission tomography; GATE; Geant4 Application for Tomographic Emission; LLD; M09-356 GATE Simulations; Monte Carlo simulations; NIM electronics; PET; Siemens Inveon detectors; cell trafficking studies; data acquisition card; intrinsic photopeak; ion source; lower level discriminator; lutetium-based scintillators intrinsic activity; positron emission tomography; proposed scanners design; proposed scanners simulation; routine scanning; scintillator crystals; small animal imaging; wide energy window; Animals; Data acquisition; Detectors; Event detection; Geometry; Ion sources; Performance evaluation; Positron emission tomography; Solid modeling; Traffic control; LSO intrinsic activity; Monte Carlo simulation; coincidence; energy spectrum; positron emission tomography;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium Conference Record (NSS/MIC), 2009 IEEE
Conference_Location
Orlando, FL
ISSN
1095-7863
Print_ISBN
978-1-4244-3961-4
Electronic_ISBN
1095-7863
Type
conf
DOI
10.1109/NSSMIC.2009.5401776
Filename
5401776
Link To Document