    Simulation of ultra low-dose scans in quantum counting clinical CT

  • Author

    Weidinger, Thomas ; Buzug, Thorsten M. ; Flohr, Thomas ; Fung, George S K ; Kappler, Steffen ; Stierstorfer, Karl ; Tsui, Benjamin M W

  • Author_Institution
    Univ. of Luebeck, Luebeck, Germany
  • fYear
    2011
  • fDate
    23-29 Oct. 2011
  • Firstpage
    2495
  • Lastpage
    2499
  • Abstract
    Contrary to conventional energy integrating detectors, electronics noise in quantum counting detectors (also frequently referred to as photon counting detectors) mainly affects the spectral resolution of the detector. There is almost no impact on the counting signal itself. This promises improved image quality due to image noise reduction in scans obtained from clinical computed tomography (CT) examinations with lowest X-ray tube currents or strongly attenuating obese patients. In most of these examinations, noise from the electronics dominates the image noise when using conventional detectors. Applying quantum counting detectors instead can improve image quality of ultra low-dose scans. This improvement may as well be used to reduce X-ray dose while maintaining image noise on the level of conventional detectors. To quantify these benefits, we have simulated sinograms of various slice scans of the human body, using the parametric 3D XCAT phantom (abdomen, shoulders) and a geometric DRASIM phantom (cranium). The simulation chain includes modeling the X-ray source, beam attenuation in the patient, and calculation of the detector response followed by data corrections and image reconstruction.We quantify the image noise in selected Region Of Interest (ROI) in the difference image of two scans that differ only in their image noise realization. Furthermore, we provide a direct comparison of image noise in energy integrating and quantum counting CT system concepts.
  • Keywords
    biomedical electronics; brain; computerised tomography; diseases; image denoising; image reconstruction; medical image processing; photon counting; X-ray tube currents; abdomen; computed tomography; cranium; electronics noise; energy integrating detectors; geometric DRASIM phantom; image noise reduction; image quality; image reconstruction; obese patient; parametric 3D XCAT phantom; photon counting detector; quantum counting clinical CT; quantum counting detector; shoulders; sinogram; ultra low-dose scan; Cathodes; Detectors; Image resolution; USA Councils; X-ray imaging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2011 IEEE
  • Conference_Location
    Valencia
  • ISSN
    1082-3654
  • Print_ISBN
    978-1-4673-0118-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2011.6152676
  • Filename
    6152676