Title :
Beam test results of two kinds of high-rate multi-gap resistive plate chambers
Author :
Wang, Yi ; Wang, Jingbo ; Zhu, Xianglei ; Li, Yuanjing ; Cheng, Jianping ; Herrmann, Nobert ; Deppner, Ingo ; Zhang, Yapeng ; Loizeau, P. ; Senger, P. ; Gonzalez-Diaz, D.
fDate :
Oct. 24 2009-Nov. 1 2009
Abstract :
To improve the rate capability of MRPC, we developed pad- and strip-readout multi-gap resistive plate chambers (MRPCs) with low-resistive silicate glass electrodes (with bulk resistivity of 1010 ¿cm quantity) and studied their performances. The tests were performed with 2.5 GeV proton beam at GSI. Time resolutions below 85 ps and efficiencies larger than 90% were obtained at counting rates up to 28 kHz/cm2.
Keywords :
electrodes; position sensitive particle detectors; proton effects; GSI; beam test; bulk resistivity; electron volt energy 2.5 GeV; high rate capability; low-resistive silicate glass electrodes; multigap resistive plate chambers; pad-readout MRPC; strip-readout MRPC; Clocks; Conductivity; Electrodes; Glass; Monitoring; Nuclear and plasma sciences; Particle beams; Performance evaluation; Testing; Voltage;
Conference_Titel :
Nuclear Science Symposium Conference Record (NSS/MIC), 2009 IEEE
Conference_Location :
Orlando, FL
Print_ISBN :
978-1-4244-3961-4
Electronic_ISBN :
1095-7863
DOI :
10.1109/NSSMIC.2009.5402035