• DocumentCode
    3334693
  • Title

    Measurements of plasma parameters in atmospheric helium plasma detectors for gas chromatograph

  • Author

    Takahashi, Yuichiro ; Nagata, Yoichi ; Miyahara, Hidekazu ; Okino, Akitoshi

  • Author_Institution
    Tokyo Tech., Yokohama, Japan
  • fYear
    2010
  • fDate
    20-24 June 2010
  • Firstpage
    1
  • Lastpage
    1
  • Abstract
    Summary form only given. In the field of chemical analysis, the gas chromatograph (GC) has been widely used because of its flexibility, short measurement time and low running cost. Recently, high-sensitive detection is required for further improvement of analytical performance. To realize high sensitivity, excellent detector for GC is needed. Until now, many types of detectors have been developed. Thermal Conductivity Detector (TCD) is the most common detector and it is applicable for almost all samples. But the limit of detection (LOD) of TCD is not good, which is on the order of 100 ppm. Flame ionization detector (FID) is another excellent detector, which utilizes hydrogen flame ionization. So, FID is the best choice for detection of flammable components and it realizes excellent LOD, on the order of 10 ppb. However, FID can not be applicable for detection of inflammable components.In this study, we developed two new detectors for GC using atmospheric pressure helium plasma. Helium has the highest ionization (24.58 eV) and excitation (19.82, 20.62 eV) energy in all elements. That means helium plasma can effectively ionize and excite all elements. In the helium plasma ionization detector (HPID), DC powered helium plasma is used for ionization of samples. The samples are ionized when it is mixed into the helium afterglow plasma. When 2 ml of 100 ppm hydrogen, nitrogen, oxygen, methane and carbon monoxide are introduced, 30-150 ppb of LOD has been achieved. On the one hand, low frequency plasma atomic emission detector (LFP-AED) was developed. This detector utilizes LF powered dielectric barrier discharge (DBD) in quartz tube for the excitation of analytes. When 1 ml of 100 ppm fluorocarbons (CH2C12, CH2Br2 and CH3CH2I) are introduced, LOD for fluorine, chlorine and bromine are 100 ppb for each. For pursuing further improvement of analytical performance, the fundamental plasma properties were measured using spectroscopic method. The emission properties, the excitati- n temperature and the electron number density were measured using spectroscopic method. The excitation temperature based on helium atomic emission lines (He I 447.15, 492.19, 501.57, 587.56 and 667.82 nm) was 2,200 ~ 2,300 K for HPID when the discharge current was changed from 5 mA to 30 mA. For LFP-AED, the excitation temperature was 2,600 K. In addition, electrode configuration and components of the plasma gas were varied to improve analytical performance. The relationship between the plasma parameters and the detection limits will be presented.
  • Keywords
    afterglows; chromatography; helium; ionisation; organic compounds; plasma density; plasma diagnostics; plasma temperature; He; LF powered dielectric barrier discharge; atmospheric pressure helium plasma detector; chemical analysis; electrode configuration; electron number density; excitation temperature; flame ionization detector; fluorocarbon; gas chromatograph; helium afterglow plasma; helium atomic emission lines; helium plasma ionization detector; high-sensitive detection; hydrogen ionization; low frequency plasma-atomic emission detector; plasma parameter measurement; pressure 1 atm; spectroscopic method; thermal conductivity detector; Atmospheric measurements; Atmospheric-pressure plasmas; Detectors; Helium; Ionization; Performance analysis; Plasma chemistry; Plasma measurements; Plasma temperature; Thermal conductivity;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Plasma Science, 2010 Abstracts IEEE International Conference on
  • Conference_Location
    Norfolk, VA
  • ISSN
    0730-9244
  • Print_ISBN
    978-1-4244-5474-7
  • Electronic_ISBN
    0730-9244
  • Type

    conf

  • DOI
    10.1109/PLASMA.2010.5534325
  • Filename
    5534325