Abstract
This paper gives the distribution laws of the induced potential and induced current along a telecommunication line affected by a power line as the length of the TL is longer than the length of exposure. The terminal impedances at the both ends of the transmission line are arbitrary. The precise formulae are given for calculating the current passing through the human body in contact with the affected line
Keywords
current distribution; electric impedance; electric potential; electromagnetic induction; personnel; power transmission lines; safety; telecommunication transmission lines; transmission line theory; communication lines; distribution laws; exposure length; human body; induced current; induced potential; maintenance personnel safety; power lin; terminal impedances; Couplings; Current measurement; Electromagnetic compatibility; Humans; Impedance measurement; Laboratories; Personnel; Protection; Safety; Voltage;