• DocumentCode
    3336743
  • Title

    On the safety of maintenance personnel of communication lines

  • Author

    Yougang, Gao

  • Author_Institution
    EMC Res. Lab., Beijing Univ. of Posts & Telecommun., China
  • fYear
    195
  • fDate
    14-18 Aug 195
  • Firstpage
    607
  • Lastpage
    610
  • Abstract
    This paper gives the distribution laws of the induced potential and induced current along a telecommunication line affected by a power line as the length of the TL is longer than the length of exposure. The terminal impedances at the both ends of the transmission line are arbitrary. The precise formulae are given for calculating the current passing through the human body in contact with the affected line
  • Keywords
    current distribution; electric impedance; electric potential; electromagnetic induction; personnel; power transmission lines; safety; telecommunication transmission lines; transmission line theory; communication lines; distribution laws; exposure length; human body; induced current; induced potential; maintenance personnel safety; power lin; terminal impedances; Couplings; Current measurement; Electromagnetic compatibility; Humans; Impedance measurement; Laboratories; Personnel; Protection; Safety; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility, 1995. Symposium Record., 1995 IEEE International Symposium on
  • Conference_Location
    Atlanta, GA
  • Print_ISBN
    0-7803-3608-9
  • Type

    conf

  • DOI
    10.1109/ISEMC.1995.523629
  • Filename
    523629