  • Abstract
    The pre-alignment and active control method for the Compact Linear Collider (CLIC) is described. Two new types of instruments are used in this system-a biaxial Wire Positioning System (WPS) which uses a stretched wire as the spatial reference, and a capacitive three axes Tilt Meter System (TMS). The instruments, and the way they are used with the well-known Hydrostatic Levelling System (HLS) are described
  • Keywords
    accelerator control systems; electron accelerators; linear colliders; particle beam diagnostics; position control; CLIC; Compact Linear Collider; active control method; biaxial wire positioning system; capacitive three axes tilt meter system; double-wire method; hydrostatic levelling system; pre-alignment; Acceleration; Current measurement; Instruments; Linear particle accelerator; Magnetic sensors; Mechanical sensors; Mechanical variables measurement; Position measurement; Structural beams; Wire;