Energy-resolved photon-counting x-ray imaging arrays for clinical K-edge CT
Author
Barber, William C. ; Nygard, Einar ; Wessel, Jan C. ; Malakhov, Nail ; Wawrzyniak, Gregor ; Hartsough, Neal E. ; Gandhi, Thulasi ; Iwanczyk, Jan S.
Author_Institution
DxRay Inc., Northridge, CA, USA
fYear
2011
fDate
23-29 Oct. 2011
Firstpage
4441
Lastpage
4446
Abstract
We have fabricated a fast energy-resolved photon-counting x-ray imaging array using pixellated cadmium telluride (CdTe) semiconductor sensors and have achieved an output count rate (OCR) exceeding 20 million counts per second per square mm (Mcps/mm2) measured with a clinical computed tomography (CT) x-ray source. We have also fabricated a fast application specific integrated circuit (ASIC) with a two dimensional (2D) array of inputs for readout from pixellated direct-conversion CdTe or cadmium zinc telluride (CdZnTe) sensors. The new 2D ASICs have four energy bins with a linear energy response across the entire dynamic range for clinical CT, which is between 30 keV and 140 keV. We have measured several important performance parameters including an energy resolution of 8 keV FWHM across the entire dynamic range and a noise floor less than 23 keV by connecting the 2D ASIC to a CdTe sensor. The uniform energy resolution over the entire dynamic range is an indication of good charge collection from the direct conversion sensors. The energy resolution is maintained at high flux over long varying exposure to x-rays indicating polarization free performance from the sensors. Our results demonstrate fast output count rates from a clinical CT x-ray source, with good energy resolution and a low noise floor. The sensors and ASICs are designed to fit into existing clinical CT systems.
Keywords
II-VI semiconductors; application specific integrated circuits; cadmium compounds; computerised tomography; photon counting; semiconductor counters; zinc compounds; 2D ASIC; 2D array; CdTe; CdZnTe; application specific integrated circuit; clinical K-edge CT; clinical computed tomography X-ray source; energy resolution; energy-resolved photon-counting X-ray imaging array; noise floor; pixellated cadmium telluride semiconductor sensors; pixellated direct-conversion sensors; Computed tomography; Energy resolution; Image resolution; RNA;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2011 IEEE
Conference_Location
Valencia
ISSN
1082-3654
Print_ISBN
978-1-4673-0118-3
Type
conf
DOI
10.1109/NSSMIC.2011.6153856
Filename
6153856
Link To Document