  • Abstract
    In this paper, the MCNPX code is used to optimize the moderator materials and thicknesses for a neutron detector based on a 6Li-loaded glass scintillator. It is shown that the response of the 6Li detector to a delayed-neutron-fission spectrum is comparable to a 3He-based gas proportional counter that is configured with a similar active area and moderator materials. For a delayed-neutron spectrum, a polyethylene thickness between 4 cm and 5 cm optimizes the number of 6Li(n,α)3H reactions in the glass. Furthermore, when the polyethylene is surrounded by additional thickness of 2-cm of Flexi-boron the response of the detector to neutrons with energies of 1-100 eV (where the emission of delayed fission neutrons is small) is reduced by a factor of two or more while reducing the response at the peak of the delayed spectrum by only 20-30%. The addition of this thick Flexi-boron layer can be an effective way to reduce the unwanted signals from cosmic-ray neutrons and other background sources. A good neutron detector should also be able to distinguish between high-energy gamma-rays and neutrons. In a pulsed-power environment, the bremsstrahlung from the generator can also temporarily blind the detector. Lead shielding can be used to reduce these effects so that the detector can recover fast enough to measure delayed fission neutrons. We have used MCNPX to address the effects of lead shielding on the response of the 6Li detector to delayed fission neutrons. It is found that the addition of lead has little effect on the optimum polyethylene thickness. The addition of 5-cm-thick lead (10-cm) reduces the response to the delayed neutron spectrum by about 30% (50%) while reducing the effects of 1 MeV gamma-rays by a factor of 30 (1000).
  • Keywords
    Monte Carlo methods; bremsstrahlung; fission; neutron detection; neutron-nucleus reactions; nuclei with mass number 6 to 19; solid scintillation detectors; 3He-based gas proportional counter; 6Li(n,alpha)3H; 6Li-loaded glass scintillator; Flexi-boron layer; MCNPX; MCNPX code; bremsstrahlung; delayed neutron spectrum; delayed-neutron-fission spectrum; detecting fission neutrons; high-energy gamma-rays; lead shielding; neutron detector designs; polyethylene; pulsed-power environment; Copper; Laboratories; Lead;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2011 IEEE
  • Conference_Location
    Valencia
  • ISSN
    1082-3654
  • Print_ISBN
    978-1-4673-0118-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2011.6154519
  • Filename
    6154519