  • Abstract
    In this paper, a new method that can diagnose the cell frequencies in a cavity without a perturbing probe is presented. The cell frequencies and couplings between cells are estimated in terms of the measured pass-band performance. This method will simplify the tuning processes and make the tuning of a sealed cavity possible. It has been well checked with some numerical examples
  • Keywords
    accelerator cavities; equivalent circuits; linear accelerators; cell frequencies; coupled cavity chain; couplings; linear accelerator; pass-band; sealed cavity; tuning; Coupling circuits; Data acquisition; Data analysis; Frequency estimation; Frequency measurement; Probes; Radio frequency; Resonance; Resonant frequency; Tuning;