Title :
Resonant fatigue testing machine frequency lock based on fuzzy logic technique
Author :
Xingjian, Ji ; Jianxing, Zhou
Author_Institution :
Moe Key Lab. of Mech. Manuf. & Autom., Zhejiang Univ. of Technol., Hangzhou, China
Abstract :
The paper discussed the method of resonant frequency lock based on fuzzy logic control technique. Detailed illustration of fuzzy logic control to the resonant fatigue testing machines is presented. At last experiment result based on fuzzy logic control is compared to the conventional PID method.
Keywords :
fatigue testing; fuzzy control; resonance; test equipment; PID method; fuzzy logic control; resonant fatigue testing machine frequency lock; Control systems; Fatigue; Fuzzy control; Fuzzy logic; Fuzzy sets; Logic testing; Resonance; Resonant frequency; Springs; System testing; frequency lock; fuzzy logic; resonant frequency;
Conference_Titel :
Mechanic Automation and Control Engineering (MACE), 2010 International Conference on
Conference_Location :
Wuhan
Print_ISBN :
978-1-4244-7737-1
DOI :
10.1109/MACE.2010.5536220