Measurement of swine aortic resistivity
Author
Tsai, Jang-Zern ; Cao, Hong ; Tungjitkusolmun, Supan ; Webster, John G.
Author_Institution
Dept. of Electr. & Comput. Eng., Wisconsin Univ., Madison, WI, USA
Volume
1
fYear
1997
fDate
30 Oct-2 Nov 1997
Firstpage
152
Abstract
The authors measured impedance of swine aorta from 10 Hz to 500 kHz. The resistivity is 184 Ω·cm at low frequencies, it starts to decrease above 10 kHz and becomes 149 Ω·cm at 500 kHz
Keywords
bioelectric phenomena; biological techniques; blood vessels; electrical resistivity; 10 Hz to 500 kHz; blood vessel electrical properties; cardiac arrhythmias; excitable tissue; radiofrequency catheter ablation; swine aortic resistivity measurement; tissue conductivity; tissue impedance; ventricular tachycardia; Biomedical measurements; Catheters; Conductivity; Electrodes; Frequency measurement; Heart; Impedance; Myocardium; Radio frequency; Strips;