• DocumentCode
    3371565
  • Title

    Experimental Study of the Multichanneling, 3 MV Rimfire Gas Switch in the Self Breakdown Mode

  • Author

    Kemp, M.A. ; Curry, R.D. ; Kovaleski, S.D. ; Struve, K.W.

  • Author_Institution
    Univ. of Missouri-Columbia, Columbia, MO
  • fYear
    2005
  • fDate
    13-17 June 2005
  • Firstpage
    746
  • Lastpage
    750
  • Abstract
    Many accelerators at Sandia National Laboratories utilize the Rimfire gas switch for high voltage, high power switching. In addition, there are many multichannel closing switches used in pulsed power applications. This paper presents a brief overview of a study of the multichanneling section of the Rimfire switch. The effects of multichanneling and a method to force multichanneling are presented.
  • Keywords
    electric breakdown; pulsed power switches; switchgear; Rimfire gas switch; high power switching; multichanneling; pulsed power applications; self breakdown mode; Capacitors; Dielectrics; Electric breakdown; Electrodes; Inductance; Laboratories; Switches; Testing; Voltage; Water storage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Pulsed Power Conference, 2005 IEEE
  • Conference_Location
    Monterey, CA
  • Print_ISBN
    0-7803-9189-6
  • Electronic_ISBN
    0-7803-9190-x
  • Type

    conf

  • DOI
    10.1109/PPC.2005.300769
  • Filename
    4084325