DocumentCode :
3372782
Title :
Comparison of three methods to measure the internal pressure of empty MEMS packages
Author :
Wang, B. ; Tanaka, S. ; De Coster, J. ; Severi, Simone ; Witvrouw, A. ; Wevers, M. ; De Wolf, I.
Author_Institution :
imec, Leuven, Belgium
fYear :
2012
fDate :
2-6 July 2012
Firstpage :
1
Lastpage :
4
Abstract :
Three different measurement methods for the measurement of the pressure inside empty MEMS packages are demonstrated and discussed. They are based on measurements of capacitance, cap resonance or cap buckling. The capacitance measurement method is shown to be the most sensitive of the three methods for this application, with a pressure resolution of 11mbar.
Keywords :
capacitance measurement; micromechanical devices; cap buckling; cap resonance; capacitance measurement method; empty MEMS package; internal pressure; Capacitance; Capacitance measurement; Frequency measurement; Micromechanical devices; Packaging; Pressure measurement; Resonant frequency;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Physical and Failure Analysis of Integrated Circuits (IPFA), 2012 19th IEEE International Symposium on the
Conference_Location :
Singapore
ISSN :
1946-1542
Print_ISBN :
978-1-4673-0980-6
Type :
conf
DOI :
10.1109/IPFA.2012.6306268
Filename :
6306268
Link To Document :
بازگشت