• DocumentCode
    3379101
  • Title

    An improved failure model of oil-paper insulation at pulsating DC voltages

  • Author

    Yan Wang ; Jian Li ; Lianwei Bao ; Peng Sun ; Chenmeng Xiang

  • Author_Institution
    State Key Lab. of Power Transm. Equip. & Syst. Security & New Technol., Chongqing Univ., Chongqing, China
  • fYear
    2013
  • fDate
    20-23 Oct. 2013
  • Firstpage
    176
  • Lastpage
    179
  • Abstract
    This paper presented the improved failure model by experimental and analysis results on electrical breakdown characteristics of oil-paper insulation at pulsating DC voltages. The time-to-breakdown of oil-paper specimens were measured by using constant-stress tests. The improved failure model was established and calculated by the parameters of Weibull model and the improved competing risk algorithm. It optimizes the faults of traditional two-parameter Weibull distribution when both time and voltage are considered as variables in estimating the lifetime of oil-impregnated paper.
  • Keywords
    Weibull distribution; electric breakdown; failure analysis; impregnated insulation; insulating oils; paper; Weibull distribution; Weibull model; constant-stress tests; electrical breakdown; failure model; oil-impregnated paper; oil-paper insulation; pulsating DC voltages; time-to-breakdown; Breakdown voltage; Electric breakdown; Oil insulation; Power transformer insulation; Weibull distribution;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation and Dielectric Phenomena (CEIDP), 2013 IEEE Conference on
  • Conference_Location
    Shenzhen
  • Type

    conf

  • DOI
    10.1109/CEIDP.2013.6747429
  • Filename
    6747429